Single module 21kW -Rack Mounted Liquid Cooling Load Bank
With the advent of the era of the Internet of everything, the energy consumption problem of data centers has become increasingly prominent. In order to achieve the goal of carbon neutrality, green data centers using liquid cooling technology have received more and more attention and application.
Request for quotation

Rack Mounted Type Liquid-cooled Load Bank

With the advent of the era of the Internet of everything, the energy consumption problem of data centers has become increasingly prominent. In order to achieve the goal of carbon neutrality, green data centers using liquid cooling technology have received more and more attention and application. 


The liquid-cooled load developed by Sunwin company for green data centers has greatly reduced power consumption and has the advantages of no noise, fast heat conduction, constant power, and AC/DC universality, providing users with a more energy-saving and efficient solution.


Main Features

 

Ultra-quiet

Adopting liquid cooling, no fan is required. Under the same cooling conditions, no noisy noise is generated, creating a quiet and comfortable working environment.

 

Fast cooling

The heat conduction capacity of liquid is 25 times that of air, with higher heat dissipation efficiency, lower operating temperature, lower component loss than air-cooled load, longer life, and 30%-50% power consumption can be saved.

 

Simulation of real working conditions

It is more compatible with liquid-cooled data centers, and can simulate and verify the actual heating conditions, cooling effects, power supply load capacity, line reliability, etc. of the server in the computer room.

 

Expandability

Multiple rack-mounted modules can be connected in parallel to form a cabinet-type load, and multiple cabinets can be connected in parallel to form any power. Standard interfaces are used between modules, which is convenient for expansion and upgrading.

 

Universal AC and DC

Both AC and DC power supplies can be tested, with wide applicability, and 1kW step value can be adjusted to meet the power supply tests of computer rooms of various forms and different powers.

 

Status monitoring

The LCD screen can display information and parameters such as inlet and outlet water pressure, inlet and outlet water temperature, flow, water tank temperature, alarm, etc., to control the working dynamics in real time.

 

Technical Parameters

VoltageAC220V50Hz / DC270V
Rated PowerSingle module 21kW, Multiple units can be connected in parallel
Step Value1KW
Resistor MaterialPTC
Full load accuracyAccuracy s±5% (temperature 30°C, flow rate 2m/h)
Inlet water temperature5-50℃
Working pressure0.8MPa working pressure, ultimate test pressure 1.2 times of working pressure.
Water flow0.5-5m3/h
Inlet and outlet water temperature difference≤5℃
Pipe materialStainless Steel 304
CleanlinessPH (6-8), turbidity (less than 10NTU), conductivity (<10Us/cm), calcium hardness (measured in CaCO3), particle diameter>0.1mm
Insulation ClassF
Instrument display Front panel inlet and outlet water temperature display
Protection functionOver temperature alarm indicator (threshold 75℃)
Conduction modeOnboard
Dimension431mm*177mm*550mm
Optional functionIntelligent control of load increase and decrease

 